中 文
English
product center
Product Recommend
mini5.jpg
Functions and features of the Product
Welcome to use the most intelligent Wind/Solar Hybrid (Street Lamp or monitoring apparatus) Controller, which adopts the latest intelligent chips and semi-conductor technology. A new generation of wind and solar energy control system. the Product boasts the following features:
Adoption of the most advanced PWM power tracking technology to ensure optimum utilization of wind and solar energy.
Separate output from 2 loads.
Control through intelligent software to ensure precision.
Overload protection.
Load short circuit protection.
Floating charge function.
Intelligent filtering of the disturbance from short time illumination.
Intelligent wind turbine shut-down system.
Automatic identification functions of temperature sensor.
Automatic calculation of power output.
Two lamp-lighting control modes: optical control and time control.
Under the time control mode, adaption to the change of daytime and darkness; the lamp can be automatically turned on for specified time.
Under the optical control mode, the lamp-lighting is adjusted according to intensity of illumination.
Dawn lighting function (setting by producer needed)
Output of power regulation signals of street lamps.
Setting of all operational parameters possible.
High load output power.
Control ability of high current wind energy charging.
Control ability of high current solar energy charging.

Frequently asked questions and treatment processes
On-scene judgment and problem solving
1. Overload indicator flickers when controller is under load: output from this load exceeds the rated load by 10%. Please check whether there is overloading.
2. Controller shuts off the output when under load and overload indicator turns on: output from this load exceeds the rated load by 20% or there may be short circuit. Please check load condition.
3. No charging or display: open the top cap of controller and check whether DC fuse shim of controller has burnt out. If the fuse protector is detected to have burnt out, check whether polarity of chargeable battery and photocell unit is reversed. After correction, please replace with new DC fuse shim of the same specifications.
4. Out-of-function of wind turbine: When there is sufficient wind, one wind turbine stops working or turns slowly while others work normally. Please check whether rear control of wind turbine is in the same direction with wind; check whether controller indicates over-voltage. If everything turns out normal, please disconnect controller and battery; then connect to the battery after controller stops working. If wind turbine still doesn’t work or turns slowly, disconnect wind turbine and controller. If wind turbine is working normally, there is something wrong with controller intelligent shut-down system in need of replacement.
5. Over-voltage of charging: when voltage of chargeable battery exceeds the upper limit of protection voltage of over-charging by more than 5% and there is still charging current on photocell unit or wind turbine indicated by inserted ammeter, there may be damage to charging controller in need of replacement.

  
 
风光互补路灯控制器SN-WSC-B.jpg

Indicators and keys Description
设置键
Setting
Setting
过载指示
Overload 1

When load power exceeds the rated load by 10% in load 1, the indicator flickers for two minutes, output from this load is ceased and indicator turns on. When load power exceeds the rated load by 20% in load 1, the load output is ceased immediately and indicator turns on. When short circuit is detected during operation, the load output is ceased immediately and indicator turns on. Controller will be restarted automatically after two minutes.

过载指示
Overload 2

When load power exceeds the rated load by 10% in load 2, the indicator flickers for two minutes, output from this load is ceased and indicator turns on. When load power exceeds the rated load by 20% in load 2, the load output is ceased immediately and indicator turns on. When short circuit is detected during operation, the load output is ceased immediately and indicator turns on. Controller will be restarted automatically after two minutes.

控制器欠压指示
Under-voltage

The indicator will turn on when the controller detects that chargeable battery voltage is below the set lower limit; the indicator turns off when voltage returns within normal limits.

控制器过压指示
Over-voltage

ndicator will turn on when controller detects that chargeable battery voltage exceeds the upper limit; indicator turns off when voltage is reduced to within normal limit. Overvoltage causes the controller to disconnect solar energy charging and start up the intelligent wind turbine shut-down system.

控制器充电指示
Charging

The indicator flickers when the battery is being charged by wind or solar energy; the indicator is off when there is no charging.

Display window LED LED displays all data of controller
Connector connect wind turbine、solar pannel、load、battery
         Factory initial set-parameters
Controller Model 24V wind solar street light controller 12V wind solar street light controller
Over-charging voltage 29.6V 14.8V

Over-charging restoration

28V 14V

Load 1 over-discharging voltage

21.V 10.5V

Load 1 over-discharging restoration

24.6V 12.3V

Load 2 over-discharging voltage

21V 10.5V

Load 2 over-discharging restoration

24.6V 12.3V

Charging current of solar energy

15A

Light of load 1 on

6hours

Light of load 2 on

2hours

Time of daybreak

Auto

Light on duration before daybreak

0hours

Time of dusk

Auto
            Wind solar street light controller specifications
Controller Model 24V wind solar street lightcontroller 12Vwind solar street lightcontroller

Rated voltage of chargeable battery

24V 12V

rated power of wind turbine

600W 400W

Range of input current

0-30A 0-30A
Maximum rated power of wind turbine 600W 400W

Trigger voltage of shut-down system

≥29V ≥14.5V

Maximum charging current

12A 12A
Protection voltage of over-discharging 21V 10.5V
Restoring voltage of over-discharging 24.6V 12.3V

Output protection power

Single circuit 220W (resistive load)

Single circuit 120W (resistive load)

Rated output current 10A 10A
            Environment and safety

Measurement (length*wide*height)

177mm*135mm*56mm

Weight(kg)

1.4

Operating temperature

-40℃~+45℃

Transport/storage temperature

-40℃~+85℃

Operating humidity

0~95%R.H.(No condensation)

Operating altitude

Maximum altitude 3000m

Protection grade

IP22

Safety

LVD EN60950-0

EMC (Electro Magnetic Compatibility)

25A*2
EMC(Electro Magnetic Compatibility) FCC PART 15 CALSSB,EN55022/24,EN61000-4

Quality certification

CE

Installation instructions
Cautions
1.No exposure to rain.
2.Vertical hanging for installation.
3.Make sure the polarity of chargeable battery, load and photocell board is not reversed
4.Load power should not exceed rated power or current.
5.Keep good ventilation of controller for radiation.
6.Regular inspection of working condition of controller in case of adverse impact.

Installation procedures
1.Check whether the voltage and power of the controller matches with those of wind turbine, solar array and chargeable battery.
2.Set operating mode in accordance with service condition. Please refer to mode setting.
3.Check with universal electric meter whether the voltage of battery packs is correct and confirm anode and cathode of battery pack.
4.Connect chargeable battery pack to controller.
5.Connect applicable direct current load or lamps to controller (Please mind the polarity!).
6.Connect wind turbine to controller (It is not advisable to install while wind turbine is at high rotary speed. Connect when not rotating).
7.Check with universal electrical meter whether voltage of photoelectrical cell unit is correct (It is normal when the open circuit voltage of photocell is 1.5 times as nominal voltage.).
8.Connect solar energy battery pack to controller (Please mind the polarity!).
9.Under twin lamp mode, lamp of short working time should be connected to load 1 and that of long working time should be connected to load 2.

 

 

更多